Ventilation

Home

Glossary

Green Building Glossary

Ventilation

🏗 Building Design & Envelope

Ventilation

التهوية

📁 Building Design & Envelope
🏛 ASHRAE · Dubai Municipality · Al Sa’fat · UAE Fire Code
🇦🇪 UAE Regulatory Context

ASHRAE 62.1
Primary Ventilation Standard
10 L/s
Min. Outdoor Air per Person — Offices
ERV
Key Energy Recovery Technology
Mandatory
Mechanical Ventilation UAE High-Rise
English Term
Ventilation

Arabic Term
التهوية

Authority / Standard
ASHRAE · Dubai Municipality · Al Sa’fat · UAE Fire Code

Key Standards
ASHRAE 62.1 · ASHRAE 170 · Al Sa’fat · UAE Fire and Life Safety Code · BS EN 15251

Tags
VentilationASHRAE 62.1IAQAl Sa’fatMechanical VentilationERV
🇬🇧
English Definition

The intentional introduction of outdoor air into a building to dilute and remove indoor pollutants, control humidity, and maintain occupant health and comfort — a mandatory requirement under ASHRAE 62.1 and UAE green building regulations, balanced against the energy cost of conditioning incoming outdoor air.

The Purpose of Ventilation

Ventilation is the process of introducing outdoor air into a building to replace or dilute stale indoor air — removing carbon dioxide, body odours, volatile organic compounds, moisture, and other pollutants generated by occupant activities and building materials. Adequate ventilation is a fundamental requirement for occupant health: insufficient ventilation concentrates pollutants, raises CO₂ levels, promotes moisture accumulation and mould growth, and is directly linked to Sick Building Syndrome (SBS) symptoms including headaches, fatigue, and respiratory irritation.

Ventilation Strategies

Three primary ventilation strategies are applicable in buildings. Natural ventilation uses wind pressure and buoyancy to drive air movement through openings in the building envelope — highly energy-efficient but limited in applicability in the UAE due to extreme outdoor temperatures, high humidity, dust, and urban noise. Natural ventilation is most viable in transitional season periods (October–November and March–April in the UAE) and in certain low-rise residential typologies. Mechanical ventilation uses fans and ductwork to supply filtered outdoor air to occupied spaces and extract stale air — the standard approach in UAE commercial buildings. Mixed-mode ventilation combines natural and mechanical approaches, switching between strategies depending on outdoor conditions — an increasingly explored strategy for UAE buildings seeking to reduce mechanical ventilation energy consumption during the cooler months.

ASHRAE 62.1 Requirements and Energy Implications

The ventilation standard for commercial buildings in the UAE is ASHRAE 62.1, which specifies minimum outdoor air supply rates for different occupancy categories: for typical office spaces, the minimum is approximately 10 litres per second per person plus a floor area component. These rates must be maintained under all occupied conditions by the HVAC system’s fresh air handling equipment.

Ventilation represents a significant energy cost in the UAE — incoming outdoor air at 42°C and high humidity must be cooled and dehumidified to supply air conditions before reaching the occupied space. Energy Recovery Ventilators (ERVs) recover heat and moisture from the exhaust air stream to pre-condition the incoming outdoor air, reducing the ventilation energy penalty by 50–70%. Under Al Sa’fat and LEED, ERVs on ventilation systems earn energy performance credits, and ventilation rates above the minimum earn indoor environment quality credits — creating alignment between indoor air quality and energy efficiency objectives.

Arabic / العربية
التعريف بالعربية
🇦🇪

الإدخال المتعمَّد للهواء الخارجي إلى المبنى لتخفيف الملوثات الداخلية وإزالتها والتحكم في الرطوبة والحفاظ على صحة الشاغلين وراحتهم — متطلب إلزامي بموجب ASHRAE 62.1 ولوائح البناء الأخضر الإماراتية، يُوازَن مع تكلفة الطاقة اللازمة لتكييف الهواء الخارجي الوارد.

الغرض من التهوية

التهوية هي عملية إدخال الهواء الخارجي إلى المبنى لاستبدال الهواء الداخلي الراكد أو تخفيفه — مُزيلةً ثاني أكسيد الكربون والروائح الجسدية والمركبات العضوية المتطايرة والرطوبة والملوثات الأخرى الناتجة عن أنشطة الشاغلين ومواد البناء. والتهوية الكافية متطلب أساسي لصحة الشاغلين: تُركِّز التهوية غير الكافية الملوثات وترفع مستويات CO₂ وتُشجِّع تراكم الرطوبة ونمو العفن.

استراتيجيات التهوية

ثمة ثلاث استراتيجيات تهوية رئيسية قابلة للتطبيق في المباني. التهوية الطبيعية تستخدم ضغط الرياح والطفو لدفع حركة الهواء — عالية الكفاءة طاقوياً لكن محدودة التطبيق في الإمارات بسبب درجات الحرارة الخارجية القصوى والرطوبة العالية والغبار. والتهوية الميكانيكية تستخدم المراوح وشبكات القنوات لتزويد الفضاءات المشغولة بهواء خارجي مُرشَّح وسحب الهواء الراكد — النهج القياسي في المباني التجارية الإماراتية. والتهوية المختلطة تجمع بين النهجين الطبيعي والميكانيكي.

متطلبات ASHRAE 62.1 وانعكاساتها على الطاقة

المعيار المرجعي للتهوية في المباني التجارية الإماراتية هو ASHRAE 62.1، الذي يحدد الحد الأدنى من معدلات تزويد الهواء الخارجي لفئات الإشغال المختلفة: في الفضاءات المكتبية النموذجية، يبلغ الحد الأدنى نحو 10 لتر/ثانية لكل شخص زائداً مكوناً لمساحة الأرضية.

تُمثّل التهوية تكلفة طاقة كبيرة في الإمارات — يجب تبريد الهواء الخارجي الوارد عند 42°م وتجفيفه لتحقيق ظروف هواء التغذية. وتسترجع أجهزة استرجاع الطاقة (ERVs) الحرارة والرطوبة من تيار هواء العادم لمعالجة الهواء الخارجي الوارد مسبقاً، مما يُقلِّل تكلفة طاقة التهوية بنسبة 50–70%. وبموجب نظامَي السعفات وLEED، تكسب أجهزة ERV على أنظمة التهوية نقاط الأداء الطاقوي.