Indoor Air Quality (IAQ)

Home

Glossary

Green Building Glossary

Indoor Air Quality (IAQ)

🏗 Building Design & Envelope

Indoor Air Quality (IAQ)

جودة الهواء الداخلي

📁 Building Design & Envelope
🏛 ASHRAE · Dubai Municipality · Al Sa’fat · WELL
🇦🇪 UAE Regulatory Context

90%
Time Spent Indoors (Average)
CO₂
Primary IAQ Indicator
ASHRAE 62.1
Ventilation Rate Standard
VOC
Key Chemical Pollutant Class
English Term
Indoor Air Quality (IAQ)

Arabic Term
جودة الهواء الداخلي

Authority / Standard
ASHRAE · Dubai Municipality · Al Sa’fat · WELL

Key Standards
ASHRAE 62.1 · Al Sa’fat IEQ · LEED IEQ · WELL v2 Air · WHO Air Quality Guidelines

Tags
Indoor Air QualityASHRAE 62.1VOCAl Sa’fatWELLOccupant Health
🇬🇧
English Definition

The condition of the air within a building as it affects occupant health, comfort, and performance — governed by ASHRAE Standard 62.1 and assessed through parameters including CO₂ levels, volatile organic compounds, particulate matter, humidity, and biological contaminants.

Why IAQ Matters in UAE Buildings

Indoor Air Quality (IAQ) refers to the chemical, physical, and biological characteristics of the air within an occupied building, assessed in terms of their effects on the health, comfort, and cognitive performance of the building’s occupants. People spend approximately 90% of their time indoors on average — a figure likely higher in the UAE, where extreme outdoor temperatures limit outdoor activity for much of the year. The quality of the air they breathe during those hours has direct and measurable effects on respiratory health, cognitive function, productivity, and absenteeism. Studies by the Harvard T.H. Chan School of Public Health have demonstrated that improvements in indoor air quality — particularly ventilation rates and VOC reduction — produce measurable improvements in cognitive function scores of 60–100%.

Key IAQ Parameters and Pollutants

IAQ is characterised through multiple parameters. Carbon dioxide (CO₂) — a metabolic byproduct of human respiration — is the most widely monitored IAQ indicator, with elevated concentrations (above 1,000 ppm) associated with reduced cognitive performance and drowsiness. CO₂ monitoring is used as a proxy for adequate ventilation. Volatile Organic Compounds (VOCs) are emitted by building materials, furnishings, cleaning products, and occupant activities; common examples include formaldehyde (from composite wood products), benzene (from adhesives), and toluene (from paints). Particulate matter (PM2.5 and PM10) — including desert dust, a significant UAE-specific concern — can penetrate deeply into the lungs and exacerbate respiratory conditions. Relative humidity outside the range of 30–60% promotes either mould growth (above 60%) or respiratory irritation and static electricity (below 30%). Biological contaminants — bacteria, mould, and Legionella in cooling towers and water systems — present specific health risks in UAE buildings.

Regulatory Framework and Green Building Credits

Ventilation for acceptable IAQ in UAE buildings is governed by ASHRAE Standard 62.1, which specifies minimum outdoor air ventilation rates for different occupancy types, expressed in litres per second per person and litres per second per square metre of floor area. Under Al Sa’fat, IAQ credits require demonstration that the HVAC system delivers ventilation rates meeting or exceeding ASHRAE 62.1 minimums, that low-VOC materials are specified for interior finishes, and that construction IAQ management procedures are implemented to prevent contamination of the building fabric during construction. The WELL Building Standard, increasingly specified on premium UAE projects, sets more demanding IAQ requirements including real-time air quality monitoring, filtration standards, and post-occupancy IAQ testing.

Arabic / العربية
التعريف بالعربية
🇦🇪

حالة الهواء داخل المبنى من حيث تأثيره على صحة الشاغلين وراحتهم وأدائهم — محكومة بمعيار ASHRAE 62.1 وتُقيَّم من خلال معاملات كمستويات CO₂ والمركبات العضوية المتطايرة والجسيمات الدقيقة والرطوبة والملوثات البيولوجية.

لماذا تُهم جودة الهواء الداخلي في المباني الإماراتية؟

تُشير جودة الهواء الداخلي إلى الخصائص الكيميائية والفيزيائية والبيولوجية للهواء داخل المبنى المشغول، وتُقيَّم من حيث آثارها على صحة الشاغلين وراحتهم وأدائهم المعرفي. يقضي الناس ما يقارب 90% من وقتهم في الداخل في المتوسط — وهو رقم يرجَّح أن يكون أعلى في الإمارات، حيث تُحدّ درجات الحرارة الخارجية القصوى من النشاط الخارجي معظم أيام السنة. وجودة الهواء الذي يتنفسونه خلال تلك الساعات تُحدث آثاراً مباشرة وقابلة للقياس على صحة الجهاز التنفسي والوظيفة المعرفية والإنتاجية والغياب.

المعاملات والملوثات الرئيسية لجودة الهواء الداخلي

تتسم جودة الهواء الداخلي بعدة معاملات. ثاني أكسيد الكربون (CO₂) — نتاج أيضي لتنفس الإنسان — هو أكثر مؤشرات جودة الهواء الداخلي مراقبةً، وترتبط التركيزات المرتفعة (فوق 1,000 جزء في المليون) بتدهور الأداء المعرفي والنعاس. والمركبات العضوية المتطايرة (VOCs) تُنبعث من مواد البناء والأثاث ومنتجات التنظيف؛ وتشمل الفورمالديهايد والبنزين والتولوين. والجسيمات الدقيقة (PM2.5 وPM10) — بما فيها غبار الصحراء الخاص بالإمارات — يمكن أن تخترق الرئتين بعمق. والرطوبة النسبية خارج نطاق 30–60% تُشجِّع نمو العفن أو تُسبِّب تهيج الجهاز التنفسي.

الإطار التنظيمي ونقاط المباني الخضراء

يُحكم التهوية للحصول على جودة هواء مقبولة في المباني الإماراتية معيار ASHRAE 62.1، الذي يُحدِّد الحد الأدنى من معدلات تهوية الهواء الخارجي لأنواع الإشغال المختلفة. وبموجب نظام السعفات، تستلزم نقاط جودة الهواء الداخلي إثبات أن نظام التكييف والتهوية يُوفِّر معدلات تهوية تستوفي الحدود الدنيا لـ ASHRAE 62.1 أو تتجاوزها، وأن المواد منخفضة VOC مُحددة للتشطيبات الداخلية. ويُحدِّد معيار مبنى WELL متطلبات أكثر صرامة تشمل مراقبة جودة الهواء في الوقت الفعلي ومعايير الترشيح واختبار جودة الهواء الداخلي بعد الإشغال.