Acoustic Performance

Home

Glossary

Green Building Glossary

Acoustic Performance

🏗 Building Design & Envelope

Acoustic Performance

الأداء الصوتي

📁 Building Design & Envelope
🏛 Dubai Municipality · Al Sa’fat · ISO · CIBSE
🇦🇪 UAE Regulatory Context

dB
Unit of Sound Measurement
35–40 dB
Target Background Level — Offices
STC
Sound Transmission Class — Partitions
WELL v2
Premium Acoustic Standard
English Term
Acoustic Performance

Arabic Term
الأداء الصوتي

Authority / Standard
Dubai Municipality · Al Sa’fat · ISO · CIBSE

Key Standards
Al Sa’fat IEQ · ISO 16283 · ISO 717 · BS 8233 · WELL v2 Sound

Tags
Acoustic PerformanceNoise ControlSTCAl Sa’fatWELLIndoor Environment
🇬🇧
English Definition

The degree to which a building’s design controls sound transmission, reverberation, and background noise levels — protecting occupants from external noise intrusion and internal noise transfer while creating acoustic environments that support productivity, privacy, and wellbeing.

Acoustic Performance in UAE Buildings

Acoustic performance encompasses all aspects of how a building manages sound: the transmission of external noise through the envelope; the transfer of sound between internal spaces; reverberation within rooms; and background noise levels from building services. In the UAE context, several acoustic challenges are particularly pronounced. External noise intrusion from construction activity, road traffic, and aircraft — especially significant in rapidly developing urban areas of Dubai and Abu Dhabi — must be controlled at the building envelope. Mechanical services noise from HVAC systems is a dominant source of background noise in UAE commercial buildings, where the continuous operation of cooling systems creates constant mechanical noise that can mask speech and disturb concentration.

Key Acoustic Metrics

Acoustic performance is quantified through several standardised metrics. Sound Reduction Index (Rw) — measured in decibels (dB) per ISO 717-1 — characterises the sound insulation performance of a building element (wall, floor, facade) in the laboratory. Apparent Sound Reduction Index (R’w) measures in-situ performance, which is typically lower than laboratory values due to flanking transmission. Sound Transmission Class (STC) is the equivalent North American metric, widely used in UAE practice due to the prevalence of US standards. Reverberation time (RT60) characterises the acoustic quality of a room — the time for sound to decay by 60 dB after the source stops — critical for speech intelligibility in meeting rooms, auditoriums, and open-plan offices. Background noise level, expressed as NC (Noise Criteria) or NR (Noise Rating) curves, defines the acceptable level of steady background noise from services.

Acoustic Requirements Under Green Building Frameworks

Under Al Sa’fat, acoustic performance contributes credits in the Indoor Environment Quality category. Requirements typically cover: minimum facade sound insulation levels for buildings adjacent to noise sources; maximum background noise levels from HVAC systems in occupied spaces; minimum partition performance between different occupancy types; and room acoustic treatment in spaces where speech intelligibility is critical. Under LEED v4.1 and the WELL Building Standard v2, acoustic requirements are more detailed: WELL v2’s Sound concept requires acoustic testing of background noise and reverberation in all regularly occupied spaces, with performance benchmarks set against ANSI/ASA S12.60 and similar standards. For high-end commercial projects in Dubai and Abu Dhabi targeting WELL certification, acoustic consultants are engaged from early design stage to model facade sound insulation, partition performance, and services noise.

Arabic / العربية
التعريف بالعربية
🇦🇪

الدرجة التي يُتحكَّم بها في التصميم المعماري في انتقال الصوت والصدى ومستويات الضوضاء الخلفية — حماية الشاغلين من تسرب الضوضاء الخارجية وانتقال الصوت الداخلي مع توفير بيئات صوتية تدعم الإنتاجية والخصوصية والرفاهية.

الأداء الصوتي في المباني الإماراتية

يشمل الأداء الصوتي جميع جوانب كيفية إدارة المبنى للصوت: انتقال الضوضاء الخارجية عبر الغلاف؛ وانتقال الصوت بين الفضاءات الداخلية؛ والصدى داخل الغرف؛ ومستويات الضوضاء الخلفية من خدمات المبنى. وفي السياق الإماراتي، ثمة تحديات صوتية بارزة بشكل خاص. تسرب الضوضاء الخارجية من أنشطة البناء وحركة المرور والطائرات — بالغ الأهمية بشكل خاص في المناطق الحضرية سريعة التطور في دبي وأبوظبي — يجب التحكم فيه عند غلاف المبنى. وضوضاء خدمات الميكانيكا من أنظمة التكييف والتهوية هي المصدر الأكبر للضوضاء الخلفية في المباني التجارية الإماراتية.

مقاييس الأداء الصوتي الرئيسية

يُحدَّد الأداء الصوتي عبر عدة مقاييس معيارية. مؤشر تخفيض الصوت (Rw) — مقاساً بالديسيبل (dB) وفق ISO 717-1 — يُوصِّف أداء عزل الصوت لعنصر من عناصر المبنى في المختبر. وفئة انتقال الصوت (STC) هي المقياس الأمريكي الشمالي المكافئ، المستخدم على نطاق واسع في الممارسة الإماراتية. وزمن الإيقاع (RT60) يُوصِّف الجودة الصوتية للغرفة — الوقت اللازم لتخفيف الصوت بمقدار 60 ديسيبل بعد توقف المصدر — بالغ الأهمية لوضوح الكلام في غرف الاجتماعات والمكاتب المفتوحة.

متطلبات المباني الخضراء للأداء الصوتي

بموجب نظام السعفات، يُسهم الأداء الصوتي في نقاط فئة جودة البيئة الداخلية. وتشمل المتطلبات عادةً: الحد الأدنى من مستويات عزل الصوت للواجهات المجاورة للمصادر الصوتية؛ والحد الأقصى لمستويات الضوضاء الخلفية من أنظمة التكييف؛ والأداء الأدنى للحواجز. ويُعدّ معيار WELL v2 الأكثر تفصيلاً، إذ يستلزم اختبار الضوضاء الخلفية والصدى في جميع الفضاءات المشغولة بانتظام مع معايير أداء محددة.