Airtightness

Home

Glossary

Green Building Glossary

Airtightness

🏗 Building Design & Envelope

Airtightness

إحكام إغلاق الهواء

📁 Building Design & Envelope
🏛 Dubai Municipality · Al Sa’fat · ASHRAE · ATTMA
🇦🇪 UAE Regulatory Context

m³/h/m²
Standard Air Permeability Unit
Blower Door
Primary Testing Method
5 m³/h/m²
Typical UAE Compliance Target
ATTMA TS1
Test Protocol Standard
English Term
Airtightness

Arabic Term
إحكام إغلاق الهواء

Authority / Standard
Dubai Municipality · Al Sa’fat · ASHRAE · ATTMA

Key Standards
Al Sa’fat · ASHRAE 90.1 · ATTMA TS1 · ISO 9972 · BS EN 13829

Tags
AirtightnessAir LeakageBlower DoorAl Sa’fatEnvelopeEnergy Efficiency
🇬🇧
English Definition

The degree to which a building’s envelope resists uncontrolled air passage through gaps, cracks, and junctions — a critical but frequently overlooked determinant of energy performance and indoor environment quality in UAE commercial and residential buildings.

Airtightness and Its Importance

Airtightness refers to the resistance of a building’s envelope to uncontrolled air infiltration — the passage of unconditioned outdoor air into the building (or conditioned indoor air out) through gaps, cracks, and imperfect junctions in the building fabric, driven by wind pressure and buoyancy (stack effect). Unlike deliberate mechanical ventilation, air infiltration is uncontrolled and delivers no ventilation benefit; it is pure energy loss. In the UAE context, infiltrating outdoor air at 42°C and high humidity carries a substantial sensible and latent heat load into the conditioned interior — increasing the cooling load of the HVAC system in direct proportion to the infiltration rate.

Measuring Airtightness

Airtightness is measured by a pressurisation test — commonly known as a blower door test — in which a calibrated fan is installed in an external doorway and used to pressurise (or depressurise) the building to a standard test pressure differential of 50 Pascals. The measured air flow rate required to maintain this pressure difference, divided by the building’s envelope area, gives the air permeability in m³/h/m² at 50 Pa — the standard metric for airtightness in commercial buildings. Lower air permeability values indicate a tighter, more energy-efficient envelope.

UAE Requirements and Practical Guidance

Under the Dubai Green Building Regulations and Al Sa’fat, airtightness requirements are increasingly being incorporated into the compliance framework, reflecting international best practice. Target air permeability values for high-performance UAE commercial buildings are typically in the range of 3–5 m³/h/m² at 50 Pa. Achieving these targets requires deliberate attention during both design and construction: continuous air barrier layers must be specified at design stage; junctions between different envelope elements — wall-to-roof, wall-to-floor, window frames, service penetrations — must be detailed to maintain continuity of the air barrier; and construction supervision must verify correct installation. Post-construction blower door testing is the only reliable method of confirming that the specified airtightness has been achieved.

Arabic / العربية
التعريف بالعربية
🇦🇪

درجة مقاومة غلاف المبنى لمرور الهواء غير المتحكَّم فيه عبر الفجوات والشقوق والوصلات — محدد بالغ الأهمية وكثيراً ما يُغفَل للأداء الطاقوي وجودة البيئة الداخلية في المباني التجارية والسكنية الإماراتية.

إحكام إغلاق الهواء وأهميته

يُشير إحكام إغلاق الهواء إلى مقاومة غلاف المبنى لتسرب الهواء غير المتحكَّم فيه — مرور الهواء الخارجي غير المكيَّف إلى المبنى (أو الهواء الداخلي المكيَّف إلى الخارج) عبر الفجوات والشقوق والوصلات غير المحكمة في نسيج المبنى. وعلى خلاف التهوية الميكانيكية المتعمَّدة، لا يُحقِّق تسرب الهواء أي فائدة تهوية؛ فهو خسارة طاقة صرفة. وفي السياق الإماراتي، يحمل الهواء الخارجي المتسرب عند 42°م وعلى رطوبة عالية حملاً حرارياً محسوساً وكامناً كبيراً في الداخل المكيَّف.

قياس إحكام إغلاق الهواء

يُقاس إحكام إغلاق الهواء بـاختبار الضغط — المعروف عموماً بـاختبار الباب النافخ (Blower Door) — الذي يُركَّب فيه مروحة مُعايَرة في فتحة باب خارجي وتُستخدم لرفع ضغط المبنى (أو تخفيضه) إلى فرق ضغط اختباري قياسي يبلغ 50 باسكال. ويُعطي معدل تدفق الهواء المقيس اللازم للحفاظ على هذا الفرق في الضغط، مقسوماً على مساحة غلاف المبنى، نفاذية الهواء بم³/ساعة/م² عند 50 باسكال.

المتطلبات الإماراتية والإرشادات العملية

بموجب لوائح المباني الخضراء في دبي والسعفات، تُدرَج متطلبات إحكام إغلاق الهواء بشكل متزايد في إطار الامتثال. وتتراوح قيم نفاذية الهواء المستهدفة للمباني التجارية الإماراتية عالية الأداء عادةً بين 3–5 م³/ساعة/م² عند 50 باسكال. ويستلزم تحقيق هذه الأهداف اهتماماً متعمَّداً في كل من التصميم والتشييد. ويُعدّ اختبار الباب النافخ بعد الإنشاء الطريقة الوحيدة الموثوقة للتأكد من تحقيق إحكام الإغلاق المحدد.