Return to Glossary Hub

Passive Design

Home

Glossary

Green Building Glossary

Passive Design

🏗 Building Design & Envelope

Passive Design

التصميم السلبي

📁 Building Design & Envelope
🏛 Dubai Municipality · Al Sa’fat · ASHRAE
🇦🇪 UAE Regulatory Context

30–50%
Cooling Load Reduction Potential
Zero Energy
Net Zero Requires Strong Passive Base
Form Follows
Climate — Core Passive Principle
First Cost
Passive Measures Cheaper than HVAC
English Term
Passive Design

Arabic Term
التصميم السلبي

Authority / Standard
Dubai Municipality · Al Sa’fat · ASHRAE

Key Standards
Al Sa’fat · ASHRAE 90.1 · Dubai Green Building Regulations · CIBSE Guide A

Tags
Passive DesignBioclimaticSolar ControlAl Sa’fatBuilding FormEnergy Efficiency
🇬🇧
English Definition

A design philosophy that uses building form, orientation, mass, envelope, and site characteristics to manage heat, light, and ventilation without mechanical energy input — reducing the demand placed on active systems and forming the essential foundation of any net zero or high-performance building in the UAE.

The Passive Design Philosophy

Passive design is the approach to building design that harnesses the natural physical processes of the local climate — solar radiation, wind, diurnal temperature variation, and sky conditions — to regulate internal temperatures, provide natural lighting, and promote air movement, without the use of mechanical or electrical energy. In its purest form, a passively designed building maintains comfortable conditions through its physical form alone. In practice, and particularly in the UAE’s extreme climate, passive design reduces the demand placed on active systems, enabling smaller, more efficient mechanical plant and dramatically lower energy consumption over the building’s life.

Core Passive Design Strategies for the UAE Climate

The UAE’s climate — characterised by high solar radiation, extreme summer temperatures, high humidity on the coast, and significant diurnal temperature variation in the desert interior — demands specific passive strategies. Building orientation is the most fundamental: orienting the long axis of the building east-west minimises exposure of the larger facades to the low-angle east and west sun, which is difficult to shade effectively. Compact building form — minimising the surface-area-to-volume ratio — reduces the envelope area through which heat can be gained. High-performance insulation on all opaque envelope elements slows heat transfer. External shading of glazed openings prevents solar heat gain at source. High thermal mass on internal elements — concrete structure — absorbs heat gains during the day and releases them slowly, reducing peak cooling load.

Passive Design in UAE Green Building Frameworks

Passive design measures are rewarded throughout UAE green building rating systems. Under Al Sa’fat, passive strategies contribute to the Energy category credits through their effect on reducing the building’s energy consumption relative to the baseline — demonstrated through energy modelling. Projects that invest heavily in passive design typically find that the reduced HVAC plant size and annual energy savings provide a superior financial return compared to the same capital investment in active system upgrades.

The relationship between passive design and net zero buildings is direct: the lower the remaining energy demand after passive strategies are applied, the smaller the renewable energy generation system needed to offset it. For net zero carbon buildings in the UAE — where roof area for solar PV is typically limited relative to building floor area — minimising energy demand through passive design is not optional; it is the prerequisite for net zero viability.

Arabic / العربية
التعريف بالعربية
🇦🇪

فلسفة تصميمية تستخدم شكل المبنى وتوجيهه وكتلته وغلافه وخصائص موقعه لإدارة الحرارة والضوء والتهوية دون مدخلات طاقة ميكانيكية — تُقلِّل الطلب على الأنظمة النشطة وتُشكِّل الأساس الجوهري لأي مبنى عالي الأداء أو صافي الانبعاثات في الإمارات.

فلسفة التصميم السلبي

يُعدّ التصميم السلبي النهجَ في تصميم المباني الذي يستثمر العمليات الفيزيائية الطبيعية للمناخ المحلي — الإشعاع الشمسي والرياح والتفاوت الحراري اليومي وظروف السماء — لضبط درجات الحرارة الداخلية وتوفير الإضاءة الطبيعية وتعزيز حركة الهواء، دون استخدام طاقة ميكانيكية أو كهربائية. وعملياً، ولا سيما في المناخ الإماراتي المتطرف، يُقلِّل التصميم السلبي الطلب المفروض على الأنظمة النشطة، مما يُتيح تخصيص منظومة ميكانيكية أصغر وأكثر كفاءةً واستهلاكاً أقل للطاقة على مدار عمر المبنى.

الاستراتيجيات السلبية الجوهرية للمناخ الإماراتي

يتطلب مناخ الإمارات — الذي يتسم بالإشعاع الشمسي العالي ودرجات الحرارة الصيفية القصوى والرطوبة العالية على الساحل — استراتيجيات سلبية محددة. توجيه المبنى هو الأساس: توجيه المحور الطولي للمبنى شرقاً-غرباً يُقلِّل تعرض الواجهات الأكبر للشمس المنخفضة الزاوية من الشرق والغرب التي يصعب تظليلها بفاعلية. والشكل المعماري المضغوط** يُقلِّل نسبة المساحة السطحية إلى الحجم. والعزل الحراري العالي الأداء على جميع العناصر الصماء يُبطِّئ انتقال الحرارة. وتُكمّل الكتلة الحرارية الداخلية العالية المنظومة بامتصاص مكاسب الحرارة أثناء النهار وإطلاقها ببطء.

التصميم السلبي في أطر المباني الخضراء الإماراتية

تُكافَأ تدابير التصميم السلبي في جميع منظومات تقييم المباني الخضراء في الإمارات. وبموجب نظام السعفات، تُسهم استراتيجيات التصميم السلبي في نقاط فئة الطاقة من خلال تأثيرها في تقليل استهلاك الطاقة في المبنى مقارنةً بخط الأساس. والعلاقة بين التصميم السلبي ومباني صافي الانبعاثات الصفري مباشرة: كلما انخفض الطلب على الطاقة المتبقي بعد تطبيق الاستراتيجيات السلبية، صغُر نظام توليد الطاقة المتجددة اللازم للتعويض عنه.

Need a Green Building Consultant?

e-Basel Consultancy provides expert advisory on green building design, Al Sa’fat compliance, and building envelope optimisation across the UAE.

Get in Touch →

Permanent link to this article: https://www.e-basel.com/glossary/glossary-hub/passive-design/